After an AED has been used in a cardiac arrest, the program immediately moves into a post-event phase. Once emergency medical services have taken over, the organization needs to make sure the device is inspected, replenished, documented and returned to service as quickly as possible.
A post-event process is important because the AED may be needed again before anyone expects it.
During the rescue, follow the emergency response process
During the emergency, continue following the AED and emergency dispatcher instructions until paramedics or other appropriate responders take over. Do not remove the pads or interrupt care simply because a shock has been delivered.
After the event, follow the direction of responding emergency personnel regarding the device and any event information.
Replace single-use pads and opened supplies
AED electrode pads are single-use consumables. After they have been applied during a rescue, they need to be replaced. Opened rescue kits and other disposable accessories may also require replenishment.
The battery should be checked according to the AED manufacturer's post-use instructions. Some devices may have different battery considerations depending on the duration of the event and the number of shocks delivered.
Complete a post-use inspection before redeployment
The AED should be cleaned and inspected according to manufacturer instructions. Confirm that the readiness indicator has returned to normal, replacement pads are connected or stored correctly, the rescue kit is complete and the device is back in its assigned location.
ZOLL AED 3
AEDs such as the ZOLL AED 3 can store event information that may be useful following a rescue. The exact data-management process should follow the manufacturer's procedures and the organization's privacy and clinical governance requirements.
Stryker LIFEPAK CR2
Connected AED platforms such as selected LIFEPAK CR2 configurations may support additional data or device-management workflows. Organizations should establish in advance who is responsible for post-event data and how the device will be returned to service.
Update the AED program record
After the rescue, update the AED program record. Note that the device was used, replace consumables, record any new expiry dates and confirm the AED's location and status. If the unit is temporarily unavailable, the organization should know that immediately and have a plan for coverage.
Update TrackMyAED
TrackMyAED can provide the management layer for this process. Device records, new pad or battery expiry dates, documents, inspections and location information can be updated so the AED's program history remains current.
For a large organization, this is particularly important because the people who replace the pads may not be the same people responsible for purchasing, safety reporting or national program oversight.
Remember the responders and staff involved
A real cardiac arrest can be a significant event for employees and responders. Organizations should follow their internal critical-incident, occupational health and wellness processes where appropriate. A post-event review can also identify what worked well operationally and whether placement, training or equipment changes should be considered.
Quick answer
After an AED is used, replace used consumables, inspect and restore the device, manage any required event data, update program records and return the AED to rescue-ready status as quickly as possible.
Frequently asked questions
Can the same AED be used again?
Yes, provided it is inspected, any required consumables are replaced, the device passes its readiness checks and manufacturer instructions are followed.
Do AED pads have to be replaced after every use?
Yes. Electrode pads that have been applied during a rescue are single-use and need replacement.
Can The AEDShop help after a rescue?
The AEDShop can support customers with replacement consumables, device and program questions, and the steps required to help return the AED to service.
How The AEDShop supports your AED program
The AEDShop's relationship with a customer does not end when the AED is delivered. From product selection and deployment to TrackMyAED management, replacement consumables and post-event support, the goal is to support the complete lifecycle of the AED program.